GB 50689-2011 通信局(站)防雷与接地工程设计规范(英文版).pdf

  • GB 50689-2011 通信局(站)防雷与接地工程设计规范(英文版).pdf为pdf格式
  • 文件大小:40.7 M
  • 下载速度:极速
  • 文件评级
  • 更新时间:2021-07-29
  • 发 布 人: c915
  • 原始文件下载:
  • 原始文件是会员上传的无错版,推荐下载这个版本

  • 其他资料,pdf格式,下载需要1积分
  • 立即下载

  • word版文件下载:
  • 特别提醒:word版是本站通过人工智能从pdf转换成的word版本,正确率只有90%左右(正在通过训练继续提高准确率),排版恢复的也并不完全准确,没有进行任何人工校对,VIP会员直接免费下载即可,普通会员无法通过点数下载,算是给VIP的活动。

    特别提醒:word版是不完美的,错误较多,只能参考,有需要的可以少打一些字,别下载了找我们说word内容有问题,这是送给VIP会员的。

  • 文档部分内容预览:
  • 上传文件

    GB 50689-2011 通信局(站)防雷与接地工程设计规范(英文版)

    3.4EarthingConnection

    3.4Earthing Connection

    3.6EarthingConductor

    公路工程thing conductors that are laid across different floors or at the same floor with long lay

    ors that are laid across different floors or at the same floor with long laying

    3.7TheTypesofEquipotentialBonding

    3.8TheAccessingWaysofVariousCables

    3.13PowerDistributionSystem

    3.14.1Indoor cabling racks and various metal parts must be earthed, and electrical c

    5.1Duringselectionofroutingofopticalcable,followingsusceptiblezonesoflightningaccide ll bekeptfaraway: 1Where a sudden change occurs to the soil resistivity pio at the depth of 1Om. 2The junction of rockymountains and rice paddies or rivers, the boundary of mineral reserv boundaryofmountainforestsandgeologicalfaultzones

    4.1GeneralRequirements

    4.2TheTypesofEarthingandBonding

    heTypesofInternalEquipotentialBonding

    4.4 EarthGrid

    Fig.4.4.2Connection of ring rmain earthing conductor and earth grid 3 Besides at four corners of buildings, the ring main earthing conductor and the ring ea ctrodeshallbeinterconnectedonceeveryotherpillar

    5The Earthing of the Cables Entering into Burea

    TheLightningProtection andEarthingofCable

    5.1ExchangeBureau andDataBureau

    5.2AccessNetworkStationandModuleBureau

    5.3.1Equipmentofuserunits ofbroadbandaccess sitesmustbeearthed.

    .2For the earthing of user units of broadband access sites, rebars in the building foundation shall ectlyusedas theearthelectrode

    5.4FiberCableRepeater Station

    TheLightningProtectionandEarthingof

    6.1GeneralRequirements

    6.2.5Theearth grid form shall be in aco

    be designed according to Fig.6.2.7

    Che Earthing of Antenna and Feeding Cable

    6.4.2For feeding cables and coaxial cables, one earthing bar shall be set at the feeding cable window of equipment room, being used as the earth point of feeding cables.The earthing bar shall be connected with the earthgrid directly

    医院建设标准6.7.2Main earthing conductorsandmain earthingbars(earthingreferencepoints)shall be setcloseto Histribution boxes and thefirstlevelpower protectors,whichshallberegarded as the referencepoint, and then connected with equipment earthing bars via multistrand copper wires with the sectional area largerthan 7OmmTheearthingof all equipment shall takethis potential asthe referencepoint for equipotential bonding. 6.7.3Whenoneearthingbar is used in aequipment room,thestarearthingmode shall beadopted, and corresponding screwholes shall be reserved;the first level SPD,distribution boxes,optical cable metal intensive cores and metal protective coverings, the ground of DC power, the ground of equipment, enclosures, cabling racks etc.shall be earthed at the place nearby,and earthing conductor shallbeshortand straight. 6.7.4When two earthingbars areused in a equipment room,thefirst earthing bar should be connected with the first level SPD,distribution boxes, optical cable metal intensive cores and metal protective coverings;the second earthing bars should be connected with the ground of equipment the ground of DC power enclosures,cabling racks.The first earthing bar shall be connected with the earth grid directly.All earthing conductorshallbeshortand straight

    6.8.2Main earthing conductors in equipment rooms shall havereliable connection with earthing connections.Main earthing conductors should be laid in ring shape in equipment rooms along interior walls or geosynclines,cabling racks,and coppermaterials with the sectional area not less than9Omm? or16Omm’hot dip galvanized steel flats should be adopted.Several earthing bars may be set at the main earthingconductor.The earthingbar shallbethecopperplatewitha sizenotlessthan 4oOmmX 1oOmmX5mm,andcorresponding screwholes shallbereserved. 6.8.3All earthing bar and earthingconductors in equipment rooms shall be clearlymarkedwithlabels that cannot easilybedamped or fall off,indicating namesof earthing conductors and names of connected equipment at two ends of the earthing conductors;the earthing conductors should adopt green and yellow cables, and shall be fastened tight and neatly, and bending should beavoided.

    TheLightningProtectionandEarthingof

    7.1GeneralRequirements

    7.3Direct LightningProtection

    TheLightningProtectionandEarthingof

    新闻出版标准TheLightningProtectionandEarthing of Mici

    ....
  • 通信标准
  • 相关专题: 防雷  

相关下载

专题: 铁路标准 |电力标准 |路桥设计、计算 |建筑施工组织设计 |建筑节能 |

常用软件